FSOC ALIGNMENTSIH26169Simulation
SIM00.000s
Sim Feed Active
7 / 7 Scenarios Passed
SIH26169.STEP10.BASELINE-ACCEPTANCE
IDScenarioDETECT %RMS (deg)P95 (deg)MAX (deg)LOST (frames)STATUS
01Static Acquisition100.000.46910.28854.12750PASS
02Slow Linear Tracking100.000.39080.10284.88630PASS
03Sinusoidal Tracking100.000.54610.78990.79820PASS
04Near-FOV-Edge Acquisition100.001.56132.83059.92730PASS
05Actuator Saturation100.001.81893.272411.37790PASS
06Target Loss & Re-entry73.204.93288.82849.9692107PASS
07Open vs Closed Loop100.000.54610.78990.79820PASS
Selected Scenario
03: Sinusoidal Tracking
DETECTION100.00%
FRAMES1000
RMS0.5461°
FINAL0.5942°
P950.7899°
LOST0
Verdict
  • Finite values — no NaN / Inf
  • Monotonic timestamps · fixed 50 Hz dt
  • Command rate ≤ PID limit · applied ≤ actuator limit
  • Deterministic replay (bit-identical second run)
  • Tracking-quality gates met
STEP 10 BASELINE ACCEPTANCE: PASS. Gates frozen before evaluation in docs/16_BASELINE_ACCEPTANCE.md and pinned to v1_baseline.